SignatureRun

mouse_2609_150ms_control_iDS, run c5f2f922

Status done, stage done; requested by project lead; worker worker; started 2026-10-28 18:19 UTC, finished 2026-10-28 18:36 UTC, 1014 s; signature fb291437

Stages

StageStartedSeconds
claimed18:18:340.2
inspector18:18:3450.1
pipeline_check18:19:2424.9
baseline_rule18:19:494.0
deposit_checks18:19:533.3
analysis18:19:56836.3
render18:33:5297.3
persist18:35:294.2
critic18:35:3468.5
done18:36:420.1

Log

TimeAgentActionDetail
18:17:46admissionrecording registered{"by": "project lead", "candidate_id": "7764050e-2852-4537-8f72-eb2833c0f619", "deposit": "10.5281/zenodo.5557829", "member": "mouse_2609_150ms_control_iDS.mat", "paper": "10.1371/journal.pone.0259174", "recording_id": "669d42ed-e0bf-4229-9a5f-9301454eafe0", "run_id": "c5f2f922-0262-43d1-a88b-7c3845dcf413", "shape": [1954, 200, 200]}
18:19:49runsrun started{"checked_by": "openai:gpt-5.5", "protocol_params_version": 3, "recording_id": "669d42ed-e0bf-4229-9a5f-9301454eafe0", "run_id": "c5f2f922-0262-43d1-a88b-7c3845dcf413"}
18:35:34runssignature written{"criteria": "provisional", "holds": null, "run_id": "c5f2f922-0262-43d1-a88b-7c3845dcf413", "signature_id": "fb291437-f9f0-453c-a143-b2d9ffda8720"}

Entries from the audit log for this run; new rows and stage changes arrive by realtime while the run is open (connecting).

Pipeline check

Proceed: True; parameters v3.

FieldProtocolRecordingSeverityDetail
no mismatches
AnomalySeverityEffect on the Fixed Pipeline
Undocumented pre-deposit transformationwarnThe deposited movie contains all-negative integer values rather than raw non-negative fluorescence counts, so amplitude offsets, sign, and any prior normalization or subtraction are not documented. The fixed pipeline can still run, but voltage scale and baseline-sensitive interpretations should be treated cautiously.
Polarity confidencewarnThe measured orientation is non-inverted but low-confidence, so the pipeline should rely on its measurement-based orientation rather than dye expectation. Phase/activation conclusions that depend on polarity are less secure.
Whole-frame maskwarnBecause no depositor mask or NaN tissue mask is present, the whole 200 x 200 frame is treated as tissue by the available mask; background may enter spatial filtering, phase, and rotor analyses unless a better mask is checked or supplied.
baseline-window ruleinfoThe coded baseline rule reports ok for the protocol baseline: baseline_frames 901, factor 2.0, slowest_segment whole_recording, slowest_cycle_frames 15, required_min_frames 30, ratio 60.067. This is reported as informational only and does not determine a hold here.

The fixed protocol is applicable as a provisional mouse whole-heart optical-mapping analysis because the recording is identified as a mouse whole-heart iDS recording and no recording fact conflicts with the protocol fields; the protocol does not specify an indicator, frame rate, pixel size, or image size that would be contradicted. The admitted frame rate is 977.0 Hz from the paper methods, and the coded baseline-window rule passes for the available segment. The main limitations are not protocol mismatches but data-quality and provenance warnings: the deposited values appear transformed before deposit, polarity is low-confidence, and the available mask covers the whole frame, so results should be interpreted with those caveats rather than held.

Inspector

This is a mouse whole-heart iDS optical mapping recording with 1954 frames of 200 x 200 pixels; the admitted frame rate is 977.0 Hz and the linked paper independently states 200x200 at 977 FPS. The file is not raw non-negative fluorescence: all values are negative integers, and the deposit does not explain that transformation, although the paper documents conditioning used for analysis. The measured polarity is non-inverted but low-confidence; Di-4-ANEPPS normally dims on depolarization, so rely on measurement-based orientation rather than dye expectation. No acquisition log or stored/detected events are available, and the whole-frame mask should be replaced or checked before spatial analysis.

MeasurementValueMethod, Caveat
SNR, median (p10–p90)3.8 (3.5–4.1)assumes white noise; on temporally smoothed deposits noise is underestimated and SNR inflated
Mask coverage100.0%, 40000 of 40000 pxnonzero temporal std only (no NaN mask in deposit)
Polarityblocks 3, inverted False, blocks agreeing 2, median dvdt skew 2.585476977401413e-05sign of median per-pixel skew of dV/dt, baseline-corrected (121 frames)
Drift / bleachingbaseline change 28.5, vs beat amplitude 0.596, slow range 1.53e+03, trend, Spearman 0.474running median (195 frames) of the tissue-mean raw signal; steps from events (light, rhythm change) and depositor normalization or drift removal change or erase the baseline; bleaching cannot be separated from them here
Prior processingnegative valuesdeposit checks
Dominant cycle by block, frames0–1000: 142.9, 1000–1954: 95.4
ConcernSeverityDetail
Undocumented pre-deposit transformationwarnprior_processing flags processed_before_deposit=true solely from negative_values: min -7378.0, max -4.0, negative_frac 1.0, integer_frac 1.0. Raw fluorescence counts should be non-negative, and neither Zenodo metadata nor paper text explains the all-negative values in this deposited file.
Polarity confidencewarnMeasured polarity is inverted=false, but median_dvdt_skew is very small (0.00002585476977401413) and only 2 of 3 blocks agree; use pipeline measurement-based orientation rather than assuming raw Di-4-ANEPPS fluorescence polarity.
Whole-frame maskwarnMask coverage is 1.0 because no NaN/depositor mask exists and the mask is based only on nonzero temporal standard deviation; background may be analyzed as tissue unless a better mask is made.
SNR and processing thresholds are provisionalinfoSNR and the flags used to infer prior processing come from provisional tool thresholds/methods, and the SNR caveat says temporal smoothing would inflate SNR.

Inspector report 2026-10-28 18:19 UTC, model openai:gpt-5.5, provisional. Median per-pixel SNR over tissue is 3.84442891322745, with p10 3.5463776973489423 and p90 4.104365003976118, using all 1954 frames. The SNR method assumes white noise; if temporally smoothed before deposit, noise may be underestimated and SNR inflated. The mask includes 40000 tissue pixels out of 40000 total pixels, coverage 1.0, with 0 NaN pixels in frame 0. The mask comes only from nonzero temporal standard deviation, not from a depositor-provided NaN/tissue mask, so it may include background. No stored events were returned, the acquisition_log tool reports no acquisition log in the deposit, and detected_events returned no events. Therefore there are no logged light transitions or image baseline steps to label for this recording; in particular, there is no evidence from an acquisition log for any illumination change during the recording. The running-median tissue mean changes from -3064.182861328125 to -3035.669921875, a baseline_change of 28.512939453125, which is 0.5963059756456527 times the p5-p95 beat amplitude of 47.81595458984375. The slow_baseline_range is 1533.4964599609375 and the last slow-baseline sample jumps to -1532.091; the tool cautions that steps, normalization, or drift removal can change/erase baseline, so bleaching cannot be separated here.

Range checks

MetricSegmentValue at Run SettingCited RangeStatus
persistent rotor tracksall1104 countnone citedunstable not reportable
dominant freq (Hz)whole recording7.169 Hznone citedunstable not reportable
persistent rotorswhole recording1104 countnone citedunstable not reportable
singularity frames fractionwhole recording1 fraction of framesnone citedno cited range
persistent rotor count maxwhole recording51 countnone citedunstable not reportable

Compare

no earlier completed run of this recording to compare with; choose one in the toolbar

Statusdone
Stagedone
Heartbeat18:36:42
Log3 entries