Compare runs Export
Dataset Figures Sensitivity Report

masked_data_RG_80nM, Rat heart, ventricular fibrillation

128 × 80 px, 3,800 frames, 1 kHz, 112.5 µm/px, deposit checks: unit range, non integer, nan mask partial, temporal smoothing, spatial smoothing

Run 5ae47ba0, 2026-10-27 22:09 UTC, protocol parameters v1, code 752b95b (uncommitted changes), None workers, signature 4535f454, run view 5ae47ba0, 9 signatures of this recording

Not reportable: range check not passed, code uncommitted changes, parameters unsigned, reviewer sign-off pending; 15 rules open

Parameters

% Rat whole heart optical mapping (Zenodo 18319102), v1, read-only
% set by developer (not a domain scientist); provisional, REVIEW_NEEDED 16
baseline_frames  = 121;     % no baseline rule recorded for this run
pad_frames       = 200;     % each side, outside the window
spatial_sigma    = 1.0;     % px, Gaussian, phase only
spatial_truncate = 4.0;     % kernel radius, sigma
lowpass          = [];      % none
polarity         = 1;       % measured, skew of dV/dt
rotor_threshold  = 0.9;     % turns, |winding| per plaquette
rotor_erode_px   = 3;       % px from tissue edge ignored
link_px          = 4.0;     % tracking, max step per frame
max_gap          = 5;       % frames a track may vanish
min_cycles       = 1.0;     % own rotations, min_frames = 25
pair_dist_px     = 3.0;     % opposite-charge pairing
paired_frac      = 0.5;     % max paired fraction of a track
render_step      = 4;       % movie only

Segments

SegmentDefinedAnalysedCycle, framesExpected RotorsBounded By
Ventricular fibrillation (whole recording)0–3,800200–3,600[not measured]not statedrecording start → recording end

Frames at 3,800 total, 1.0 ms per frame. Cycle from the MAP channel of the DAQ log (median interval) when one exists, else from per-pixel dominant frequency. Boundaries, expectations and the segment design are provisional (developer (no comparison defined)).

Metrics

MetricUnitVentricular fibrillation (whole recording)Physiological Range
Rhythm
Dominant frequencyHz 40.294 none cited
Rotors
Persistent rotorscount 204–464 none cited
Max concurrent persistent rotorscount 9–21 none cited
Frames with a singularityfraction 1.000 none cited
Beats, where a global rhythm exists
Beatscount 0 none cited
Global amplitude ratioratio 0.28 gate ≥ 0.30 provisional
APD50ms no global beat none cited
APD90ms no global beat none cited
Conduction velocitycm/s no global beat none cited

Values at the run setting. Red: range across the sensitivity grid (12 baseline × sigma settings, 3 trackers) where the spread exceeds 25 % of the median; not reportable as a value. Beat metrics are not varied over the grid. Dominant frequency over the whole analysed window: 40.294 Hz. No global upstroke found (no beat-wise activation map, CV or APD for this segment).

CriterionRuleResult
Design expectationsnone stated for this recording's segmentsno criterion to test; counts are descriptive provisional

Report

The PDF carries the parameters as run, segments, metrics, criteria, reportable values, every provisional rule, the review items, the opening frame as camera, voltage and phase with the parameter footer, and the provenance block. The JSON carries the same plus the full stored metrics, sensitivity and critic records.

Methods

Using provisional parameter set version 1 for protocol a0059cf5-fbde-4942-a18f-399ebe70e9ff, the analysis would use baseline_frames = 121, spatial_sigma = 1.0, spatial_truncate = 4.0, pad_frames = 200, rotor_threshold = 0.9, rotor_erode_px = 3, link_px = 4.0, max_gap = 5, min_cycles = 1.0, pair_dist_px = 3.0, paired_frac = 0.5, and render_step = 4. The frame rate is 1000 Hz from deposit_metadata, and the pixel size is 112.5 µm from deposit_metadata. The analysed frames are 200 to 3600. The provisional segment definition is whole_recording, labelled ventricular fibrillation (whole recording), with start_frame = 0 and end_frame = 3800, defined as the whole recording with no events detected or logged; the parameter set, segment definitions, and criteria are provisional.

Reportable values

MetricSegmentValueUnitStatus
persistent rotor tracksall204–464countunstable, not reportable
dominant freq (Hz)whole recording40.29Hzno cited range
persistent rotorswhole recording204–464countunstable, not reportable
singularity frames fractionwhole recording1fraction of framesno cited range
persistent rotor count maxwhole recording9–21countunstable, not reportable

physiology_ok: not decided (no cited range passed or failed); send back: False. Verdict: physiology_ok is not decidable because there are no cited ranges for the stable descriptive metrics and the rotor-count metrics are unstable; reportable items are singularity_frames_frac as a descriptive value stable over 1.0 to 1.0 and dominant_freq_hz as a descriptive value stable over 40.294 to 40.294 Hz, while whole_recording.persistent_rotors and persistent_rotor_tracks are unstable over 204.0 to 464.0 and whole_recording.persistent_rotor_count_max is unstable over 9.0 to 21.0 and should not be reported as numeric signature metrics. The strict, default, and loose trackers found 250, 303, and 450 persistent rotors, respectively, so tracker sensitivity needs review even though the tracker agreement flag is true; the persistent-threshold variants are not applicable because there were no segment expectations. The deposit preprocessing and polarity transformation need reviewer awareness, and rotor-count interpretation should account for the same-rat context warning that naive phase-singularity detectors can produce false rotational drivers at conduction blocks (DOI 10.1371/journal.pcbi.1013963). The ranges, the stability threshold of 0.25 x median, and the criteria are provisional.

Provisional rules

Rule, LocationDescriptionExpertStatus
protocol_parameter_set
worker/voltage/protocol_params.py (developer_defaults, set_params)
Each protocol's fixed, versioned analysis parameters (version 1 = developer defaults); no run or agent may deviateoptical mapping analystprovisional
filter_defaults
worker/voltage/preprocess.py (Params)
Default baseline window (frames) and spatial Gaussian sigma/truncate for phaseoptical mapping analyst (cardiac electrophysiology)provisional
tissue_mask
worker/voltage/io.py (tissue_mask)
Tissue = not NaN in frame 0 and nonzero temporal stdoptical mapping analystprovisional
polarity
worker/voltage/preprocess.py (polarity)
Dye polarity from sign of median per-pixel skew of dV/dtoptical mapping analyst / voltage dye chemistprovisional
singularity_detection
worker/voltage/preprocess.py (Params.rotor_threshold, rotor_erode_px)
Phase singularity = |winding| > threshold turns, >= erode px from tissue edgecomputational cardiac electrophysiologist (phase mapping)provisional
rotor_persistence
worker/voltage/rotors.py (TrackParams)
Track linking distance/gap and minimum lifetime for a persistent rotorcomputational cardiac electrophysiologist (phase mapping)provisional
chirality_pairing
worker/voltage/rotors.py (TrackParams.pair_dist_px, paired_frac)
Opposite-charge singularities within pair distance are a pair; tracks paired most of their life are excluded from rotorscomputational cardiac electrophysiologist (phase mapping)provisional
sensitivity_grid
worker/voltage/sensitivity.py (SIGMAS, BASELINE_MULTIPLES, baseline_levels)
Filter levels tested: spatial sigma and baseline window valuesoptical mapping analystprovisional
analysis_window
worker/voltage/runs.py (default_window)
Frames analysed: whole recording minus one filter pad at each end (unless the plan narrows it)cardiac electrophysiologist familiar with the datasetprovisional
prior_processing_flags
worker/voltage/inspect.py (prior_processing)
Thresholds for flagging depositor processing (normalization, masking, temporal/spatial smoothing)imaging scientist (camera acquisition and noise)provisional
pipeline_check
worker/agents/pipeline.py (INSTRUCTIONS, validator)
The pipeline agent's hold/proceed decision from protocol mismatches and inspector anomalies; it chooses no parameteroptical mapping analystprovisional
physiology_reference_rates
worker/voltage/physiology.py (RANGES, TOLERANCE_FRAC)
Cited physiological ranges (single-study values widened by a 25% tolerance), applied to segments by their expected rhythm; used by the critic and for frame-rate sanity checkscardiac electrophysiologist per speciesprovisional
stability_rule
worker/agents/critic.py (STABLE_FRAC, stability)
A metric is reportable only if its spread across all sensitivity settings is <= 25% of its median (zero spread when all values are 0); otherwise 'unstable, not reportable'biostatistician + optical mapping analystprovisional
persistence_threshold_variants
worker/agents/critic.py (persistence_variants)
The persistent-rotor rule is run at two lifetimes, one measured cycle of the fastest segment and the paper's cited rotation period; both verdicts stored, disagreement flaggedcomputational cardiac electrophysiologist (phase mapping)provisional
persistent_rotor_criterion
worker/voltage/sensitivity.py (MIN_ROTORS_PRESENT, MAX_ROTORS_ABSENT)
Persistent-rotor finding holds if every 'present' segment has >= 1 persistent rotor and every 'absent' segment has none, at every settingcardiac electrophysiologistprovisional

Review items

TopicDetailSeverityReviewer
unstable:whole_recording.persistent_rotorsThe whole-recording persistent-rotor count ranged from 204.0 to 464.0 across filter grid and tracker settings, exceeding the provisional stability criterion and making the numeric count not reportable.warnautomated stability critic
unstable:whole_recording.persistent_rotor_count_maxThe whole-recording maximum simultaneous persistent-rotor count ranged from 9.0 to 21.0 across filter grid and tracker settings, exceeding the provisional stability criterion and making the numeric maximum not reportable.warnautomated stability critic
unstable:persistent_rotor_tracksPersistent rotor tracks ranged from 204.0 to 464.0 across filter grid and tracker settings, exceeding the provisional stability criterion and making the numeric track count not reportable.warnautomated stability critic
preprocessed depositThe deposit is documented as background-subtracted, spatially binned, low-pass filtered, drift-removed, and normalized, so analyses requiring raw fluorescence/counts or unfiltered noise statistics would be misleading.warnrecording inspector
polarity transformed relative to dyeRH237 normally dims on depolarization, but measured polarity is non-inverted with 7/7 blocks agreeing; the pipeline should orient from measured polarity.warnrecording inspector
SNR depends on preprocessingMedian SNR may be inflated because documented temporal filtering and detected temporal smoothing can reduce apparent frame-to-frame noise.inforecording inspector
reference thresholds provisionalNo frame-rate inference was needed because the deposit states 1 kHz, but conclusions from automated processing flags and provisional rhythm/reference-rate tools should be treated as not yet domain-scientist reviewed.inforecording inspector

Data and code availability

Recording10.5281/zenodo.18319102, CC-BY-4.0, Verstraeten, Bjorn; Lootens, Sebastiaan
Publication10.1093/cvr/cvaa141
Analysis code752b95b01dde60f86eb71b47343448c7af4551c1 (uncommitted changes)
Stored arrays[not stored]
Rundone
Review items23 open