Compare runs Export
Figures Sensitivity Report
Recordings / M13Rec001 / Signature

M13Rec001, Mouse heart, spiral wave and optogenetic termination

64 × 55 px, 9,267 frames, 1 kHz, 133 µm/px, deposit checks: negative values, nan mask all frames, temporal smoothing, spatial smoothing

Run 339921d8, 2026-10-28 18:40 UTC, protocol parameters v3, code 008c2dc (uncommitted changes), 9 workers, signature 9b40a32d, run view 339921d8, 13 signatures of this recording

Not reportable: range check not passed, code uncommitted changes, parameters unsigned, reviewer sign-off pending; 20 rules open

Parameters

% Mouse whole heart optical mapping (Luther lab), v3, read-only
% set by developer (not a domain scientist); provisional, REVIEW_NEEDED 16
baseline_frames  = 901;     % >= 2 x slowest cycle (415, MAP): ok
pad_frames       = 500;     % each side, outside the window
spatial_sigma    = 1.0;     % px, Gaussian, phase only
spatial_truncate = 4.0;     % kernel radius, sigma
lowpass          = [];      % none
polarity         = -1;      % measured, skew of dV/dt
rotor_threshold  = 0.9;     % turns, |winding| per plaquette
rotor_erode_px   = 3;       % px from tissue edge ignored
link_px          = 4.0;     % tracking, max step per frame
max_gap          = 5;       % frames a track may vanish
min_cycles       = 1.0;     % own rotations, min_frames = 52
pair_dist_px     = 3.0;     % opposite-charge pairing
paired_frac      = 0.5;     % max paired fraction of a track
render_step      = 4;       % movie only

Segments

SegmentDefinedAnalysedCycle, framesExpected RotorsBounded By
Illumination with arrhythmia0–3,170500–3,17052 (n = 53)presentLED on before frame 0 (DAQ) → termination step (image, ±17 frames)
Illumination after termination3,170–4,9773,170–4,977415 (n = 4)absenttermination step (image, ±17 frames) → illumination off (DAQ, ±11 frames)
Light off4,977–9,2674,977–8,767411 (n = 10)absentillumination off (DAQ, ±11 frames) → recording end

Frames at 9,267 total, 1.0 ms per frame. Cycle from the MAP channel of the DAQ log (median interval) when one exists, else from per-pixel dominant frequency. Boundaries, expectations and the segment design are provisional (project lead (not a domain scientist), following the paper's design, 10.1371/journal.pcbi.1011660).

Metrics

MetricUnitIllumination with arrhythmiaIllumination after terminationLight offPhysiological Range
Rhythm
Dominant frequencyHz 15.356–19.8502.2142.375 18.75–20 Hz, one recording, 10.1371/journal.pcbi.1011660, ±25% provisional
Rotors
Persistent rotorscount 4–1500 none cited
Max concurrent persistent rotorscount 1–200 none cited
Frames with a singularityfraction 0.4790.001–0.0150.003–0.030 none cited
Beats, where a global rhythm exists
Beatscount 5749 none cited
Global amplitude ratioratio 0.720.950.95 gate ≥ 0.30 provisional
APD50ms 141616 none cited
APD90ms 257675 none cited
Conduction velocitycm/s 31.358.560.0 none cited

Values at the run setting. Red: range across the sensitivity grid (12 baseline × sigma settings, 3 trackers) where the spread exceeds 25 % of the median; not reportable as a value. Beat metrics are not varied over the grid. Dominant frequency over the whole analysed window: 2.419 Hz.

CriterionRuleResult
Singularities present where the design expects them, absent elsewhereeach 'present' segment: frac >= 0.1 and >= 2.0 x max frac over 'absent' segments, at every settingholds at 12 filter settings provisional
Persistent rotors present where the design expects them, absent elsewhereeach 'present' segment: count >= 1; each 'absent' segment: count <= 0, at every settingholds at 12 filter settings and 3 trackers provisional
Persistence threshold, paper contextlifetime ≥ 52 frames (measured cycle) and ≥ 50 frames (cited 20 Hz)agree provisional
display only
cursorx –, y – value–
ROIxyValue at Frame

Figure 1. Frames 500–8,767 of 9,267, native 64 × 55 px, nearest-neighbour, no interpolation, float32 as stored. Camera: values as deposited. Voltage: baseline-corrected only (901-frame centred moving average subtracted per pixel), polarity ×-1, no spatial filter. Phase: angle of the Hilbert transform of the Gaussian-filtered signal (σ = 1.0 px), twilight. Activation and dominant frequency: per-pixel maps of the current segment (magma). Singularities (open −1, filled +1): |winding| > 0.9 turns, ≥ 3 px inside the tissue edge. Rotor tracks: persistent rotors (≥ 1 own rotation, lifetime ≥ 52 frames) drawn as rings at their mean core while alive. Mask outline: tissue mask, source nan_frame0 (NaN rule; run predates the mask rule). Opening frame 1,192, display choice: frame with the most concurrent persistent rotors (2) in illumination with arrhythmia, midpoint of the longest such stretch. Display range, display choice: voltage ±99th percentile |V| and camera 1st–99th percentile of the current segment's tissue pixels; phase −π to π.

Figure 2. Traces of the current view at the listed ROIs, from the stored arrays. ROI A (25, 25) and ROI B (46, 17): display choice: A nearest the mean persistent-rotor core, B the farthest tissue pixel from A with amplitude at or above the tissue median. Dashed lines: segment boundaries. Red: playback cursor.

Frame–
Time–
Cursor–
Segment–
Rundone
Review items32 open
space play · ← → step