masked_data_RG_80nM, Rat heart, ventricular fibrillation
128 × 80 px, 3,800 frames, 1 kHz, 112.5 µm/px, deposit checks: unit range, non integer, nan mask partial, temporal smoothing, spatial smoothing
Run 20dfde82, 2026-10-27 22:15 UTC, protocol parameters v1, code 13d8ceb, None workers, signature fb42c503, run view 20dfde82, 9 signatures of this recording
Not reportable: range check not passed, code clean, parameters unsigned, reviewer sign-off pending; 15 rules open
Properties
| Deposit | 10.5281/zenodo.18319102, https://zenodo.org/records/18319102 |
| Publication | 10.1093/cvr/cvaa141 |
| Licence | CC-BY-4.0 (as stated: cc-by-4.0) |
| Authors | Verstraeten, Bjorn; Lootens, Sebastiaan |
| File | public/masked_data_RG_80nM.mat, mat, 293,204,250 bytes |
| sha256 | 9e30977de373f78d1b5d236bd100e46bb79c72152d3a7516b9c03c4849391076 |
| Frame rate | 1000 Hz, deposit metadata 10.5281/zenodo.18319102 |
| Pixel size | 112.5 µm, deposit metadata 10.5281/zenodo.18319102, midpoint of the stated 100-125 um; conduction velocities carry a +/-11% range from this alone |
| Polarity | upright, measured |
| Segments source | developer (no comparison defined) |
| Protocol | Rat whole heart optical mapping (Zenodo 18319102), rat, whole heart; parameters v1 set by developer (not a domain scientist): version 1: the library defaults as of commit 363372b; provisional, see protocol_params.py |
| Run | 20dfde82-4f4a-4a14-9732-14f64668db46 |
| Started, finished | 2026-10-27 22:15 UTC, 2026-10-27 22:19 UTC |
| Code | 13d8ceb123e64ab2c7eaba9fbf51605361856f11 |
| Workers | [not recorded] |
| Steps | load, deposit_checks, baseline_correct, polarity, spatial_filter(phase only), hilbert_phase, phase_singularities, track_and_pair, beats_apd_cv, sensitivity, render |
| Signature | fb42c503-638b-471d-b7b2-834ee2023623, 2026-10-27 22:19 UTC |
| Movie | runs/20dfde82-4f4a-4a14-9732-14f64668db46/movie.mp4 |
| Lossless frames | [not stored] |
Parameters
% Rat whole heart optical mapping (Zenodo 18319102), v1, read-only % set by developer (not a domain scientist); provisional, REVIEW_NEEDED 16 baseline_frames = 121; % no baseline rule recorded for this run pad_frames = 200; % each side, outside the window spatial_sigma = 1.0; % px, Gaussian, phase only spatial_truncate = 4.0; % kernel radius, sigma lowpass = []; % none polarity = 1; % measured, skew of dV/dt rotor_threshold = 0.9; % turns, |winding| per plaquette rotor_erode_px = 3; % px from tissue edge ignored link_px = 4.0; % tracking, max step per frame max_gap = 5; % frames a track may vanish min_cycles = 1.0; % own rotations, min_frames = 25 pair_dist_px = 3.0; % opposite-charge pairing paired_frac = 0.5; % max paired fraction of a track render_step = 4; % movie only
Segments
| Segment | Defined | Analysed | Cycle, frames | Expected Rotors | Bounded By |
|---|---|---|---|---|---|
| Ventricular fibrillation (whole recording) | 0–3,800 | 200–3,600 | [not measured] | not stated | recording start → recording end |
Frames at 3,800 total, 1.0 ms per frame. Cycle from the MAP channel of the DAQ log (median interval) when one exists, else from per-pixel dominant frequency. Boundaries, expectations and the segment design are provisional (developer (no comparison defined)).
Metrics
| Metric | Unit | Ventricular fibrillation (whole recording) | Physiological Range |
|---|---|---|---|
| Rhythm | |||
| Dominant frequency | Hz | 40.294 | none cited |
| Rotors | |||
| Persistent rotors | count | 204–464 | none cited |
| Max concurrent persistent rotors | count | 9–21 | none cited |
| Frames with a singularity | fraction | 1.000 | none cited |
| Beats, where a global rhythm exists | |||
| Beats | count | 0 | none cited |
| Global amplitude ratio | ratio | 0.28 | gate ≥ 0.30 provisional |
| APD50 | ms | no global beat | none cited |
| APD90 | ms | no global beat | none cited |
| Conduction velocity | cm/s | no global beat | none cited |
Values at the run setting. Red: range across the sensitivity grid (12 baseline × sigma settings, 3 trackers) where the spread exceeds 25 % of the median; not reportable as a value. Beat metrics are not varied over the grid. Dominant frequency over the whole analysed window: 40.294 Hz. No global upstroke found (no beat-wise activation map, CV or APD for this segment).
| Criterion | Rule | Result |
|---|---|---|
| Design expectations | none stated for this recording's segments | no criterion to test; counts are descriptive provisional |
no lossless frames stored for this signature; run worker.voltage.frames backfill